POWAIR 2 replaces POWAIR v1 on your system so you can open existing projects and continue working seamlessly in POWAIR 2. When POWAIR 2 loads a saved POWAIR v1 instance, it automatically enters a POWAIR 1 compatibility mode. Because a few subtle underlying bugs from v1 were fixed in v2, static settings sound virtually identical (99.9%) to POWAIR 1.
Additionally, your POWAIR 2 iLok license is a group license that activates both POWAIR v1 and POWAIR 2, allowing you to move between systems running either version without authorization issues.
Important Caveats for Legacy Session Recall
While static settings and custom presets transfer cleanly, keep two details in mind when opening POWAIR v1 sessions in POWAIR 2:
1. Pro Tools Parameter Automation
To fix a bug in POWAIR v1 where automation was stepped on continuous controls, POWAIR 2 introduces a breaking change to Pro Tools parameter automation.
Sessions with written automation: Parameter automation written in POWAIR v1 will not carry over into POWAIR 2. If you have active Pro Tools projects with POWAIR automation, finish or commit/print those tracks with POWAIR v1 before upgrading.
Sessions with auto-enabled parameters (no written automation):
If you use Pro Tools' Plugin Controls Default to Auto-Enabled preference (Setup > Preferences > Mixing), your setting also won’t recall after updating to POWAIR v2.
To fix that:Open the session with POWAIR v1 installed and focus the POWAIR plug-in window.
Hold Control + Option + Command (macOS) or Control + Alt + Start (Windows) and click the Plug-in Automation Enable button (under Auto in the Pro Tools plug-in header).
Repeat for every POWAIR instance and save the session.
2. Default 2x Oversampling on Legacy Instances
Saved POWAIR v1 instances load with 2x Oversampling enabled by default in POWAIR 2. Because oversampling primarily affects the Clipper, the sonic difference on legacy instances is unnoticeable. If you prefer to disable it, click the Settings cog icon in the top-right corner of POWAIR 2 and turn Oversampling off.
Rolling Back to POWAIR v1
If you need to recall an older Pro Tools session with POWAIR v1 automation intact, you can revert to POWAIR v1 at any time:
Download the POWAIR v1 installer for your operating system:
Run the installer (on macOS, run the .pkg installer twice to cleanly overwrite POWAIR 2).
Reopen your session to load your original POWAIR v1 settings and automation.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article